To ensure reliable setup and operation of your vegaflex 62, we o. Instructions manuals for accessories and replacement parts tpi. View online operating instructions manual for vega vegaflex 86 measuring instruments or simply click download button to examine the vega vegaflex 86 guidelines. The safety instructions in this operating instructions manual, the national installation standards as well as the valid safety regulations and accident prevention rules must be observed by the user. Vega extends its portfolio of level sensors with a radar instrument series for standard measuring. Even in applications with vapour, buildup, foam generation and condensation, the sensor delivers precise and reliable measured values. Vegaflex 61 level sensor is simple to set up and has low maintenance costs thanks to the proven mechanical construction. Advantages easy mounting and installation independentof product density insensitive to vapour and condensation. Reliable measurement despite internals vegaflex series. Through a large selection of gravity weights, the vegaflex 81 can be also used in standpipes and bypass tubes. K stands for an analogue 4 20 ma output signal compact instrument v stands for a digital output signal vbus. A detachable rod antenna reduces the need for overhead clearance. List the dot set in front indicates a list with no implied sequence.
Vegadis 61 is an external indication and adjustment unit for the following vega sensors. Vega vegaflex 81 operating instructions manual pdf. To ensure reliable setup and operation of your vegaflex 61. Instructions manuals for accessories and replacement parts tip. Vega vegaflex 65 guided wave radar level sensor provides continuous level measurement for liquids in applications where reliable measurement of solvents, fuels and low viscosity liquids is required. The procedure is described in the operating instructions manual indicating and adjustment module. Vegaflex 61 foundationfieldbus tdr sensorforcontinuouslevel measurement acationareappli vegaflex 61 is a level sensor for continuous level measurement. Vegaflex 61 can fit into an existing displacer style bridle and provide measurement with no moving parts.
Even in applications with buildup, foam generation and condensation, the sensor delivers precise and reliable measured values. Vegadis 61 is an external indicating and adjustment unit for sensors. Operating instructions vegaflex 61 foundation fieldbus. Vega completes its sensor portfolio and becomes a fullrange supplier of pressure measurement technology with sensors for hygienesensitive standard applications and demanding measuring tasks.
Vegaflex 67 is a level sensor with rod, cable or coax probe for continuous interface measurement. Operating instructions vegaflex 65 profibus pa insatech. The vegaflex 81 is the economical solution for various level and interface measurements. Vegaflex 82 is a sensor for continuous level measurement.
Vega vegaflex 61 guided wave radar level sensor provides continuous level measurement for liquids and lightweight bulk solids including applications with vapour buildup, dust or condensation. Typical applications are measurements in precipitators and separators. The vegaflex 81 level sensor measures maintenancefree all kind of liquids. Instructions manuals for accessories and replacement parts. The vegaflex 86 level sensor measures maintenancefree all liquids under extreme pressure and temperature conditions. Database contains 2 vega vegaflex 63 manuals available for free online viewing or downloading in pdf. Example of vegadis 61 with plastic housing and mounting plate for wall mounting housing with electronics housing cover with indicating and adjustment. Vega vegaflex 67 operating instructions manual pdf. The new radar sensor vegapuls wl 61 covers the many areas of application in water management. View and download vega vegaflex 61 operating instructions manual online. User manuals, guides and specifications for your vega vegaflex 86 kitchen appliances, measuring instruments. Available as a twowire loop powered instrument, the vegaflex. This operating instructions provides all the information you need for mounting, connection and setup as well as important instructions for maintenance, fault.
Operating instructions at the time of shipment pdf. Recurring function test for vegaflex series 60 document id. Vegaflex 65, vega vegaflex 65 guided wave radar level. In saturated steam applications, a special reference probe ensures a densityindependent measurement. View and download vega vegaflex 81 operating instructions manual online. Database contains 11 vega vegaflex 86 manuals available for free online viewing or downloading in pdf. View and download vega vegaflex 62 operating instructions manual online. Vegadis 61 30207 electronics module vegaflex series 60. You can select this function on vegaflex via the adjustment tools. Safety manual, operating instructions manual, quick setup manual, operating instruction. Operating instructions manual 27835 indicating and adjust ment module. Level measurement in a storage vessel with vegaflex 61. There are application possibilities in nearly all areas of industry. During work on and with the device the required personal protective equipment must always be worn.
Product information vegaflex 61 vegaflex 62 vegaflex 66. The contents of this manual should be made available to. Vegaflex 86, vega vegaflex 86 guided wave radar level. Vegaflex 81 is a sensor for continuous level measurement. Operating instructions vegaflex 61 4 20 mahart fourwire document id. Vegaflex 61 is a level sensor with cable or rod probe for continuous. Vega vegaflex 81 operating instructions manual pdf download. Take note of safety instructions for ex applications. They are hence available for multiple use or service purposes. It is suitable for liquids and lightweight solids in practically all industries. Typical applications are measurements of liquids in storage vessels or bypass tubes. Vega vegaflex 86 guided wave radar level sensor provides continuous level and interface measurement for many liquids including applications with vapour buildup, foam or condensation vegaflex 86 level sensor features a shortenable specialised probe ensuring densityindependent measurement, simple standardisation and high flexibility in the planning.
Operating instructions indicating and adjustment module. Vegaflex sensors are the ideal replacement for displacer systems because they have no moving parts. Plicsmobile t61 is an external gsmgprs radio unit for transmis. User manuals, guides and specifications for your vega vegaflex 63 kitchen appliances. Typical applications are interface measurements in storage tanks, separators and pump sumps. You thus get a reliable total level as well as the level of the lower medium in your vessel. Supplementary information recurring function test for.
Pressure transmitters vegabar 52, 53, 61, 64 and 65 level sensors vegaflex 61, 62 and 65. Tdr sensor for continuous level and interface measurement of liquids, modbus and levelmaster protocol, converter version in second chamber, rod and cable probe. Indication and adjustment product information vegadis 61. You can find detailed information about the area of application in chapter product description.
View online operating instructions for vega vegaflex 83 measuring instruments or simply click download button to examine the vega vegaflex 83 guidelines offline on your desktop or laptop computer. Operating instructions vegaflex 61 profibus pa insatech. The vegaflex 83 is a level sensor with coated cable or rod probe for continuous level or. Ex specific safety instructions for ex ver sions and other. Vega vegaflex 62 operating instructions manual pdf. Vegaswing 63 twowire 29232en141015 2 for your safety 2. Vegaflex 61 is a level sensor with cable or rod probe for continuous level measurement. Vega vegaflex 61 operating instructions manual pdf. This supplementary information manual can be downloaded from our download section. You can find further information in the respective chapters of the operating instructions manual. About this document this symbol indicates special instructions for ex applications.
View and download vega vegaflex 67 operating instructions manual online. Lel measurementev of bulk solids guided microwave vegaflex 61 vegaflex 62 vegaflex 66 product information. To ensure reliable setup and operation of your vegaflex 61, we offer. View online or download vega vegaflex 61 operating instructions manual. Vega vegaflex 61 operating instructions manual pdf download. Product information vegaflex 81 vegaflex 83 vegaflex. The quick start procedure enables a quick setup with many applications.
View online operating instructions manual for vega vegaflex 83 measuring instruments or simply click download button to examine the vega vegaflex 83 guidelines offline on your desktop or laptop computer. Vegaflex can also be mounted in a standpipeor bypass tube withaninner diameterof 25 mm 1 in. Operational reliability is ensured only if the instrument is properly used according to the specifications in the operating instructions manual as well as possible supplementary instructions. Vegaflex 61 is a level sensor for continuous level measurement.
To ensure reliable setup and operation of your vegaflex 66, we o. Vegaflex 51 distinguishes the instruments according to the stability of the cable. The contacting technology of the vegaflex allows for the reliable measurement of plastic pellets. Vegadis 61 l 30207 electronics module vegaflex series 60 l 34296 protective cover. Radar sensors for the water and wastewater industry. The vegaflex 82 is a level sensor with cable or rod probe for con. For safety and warranty reasons, any invasive work on the device beyond that described in the operating instructions. Vegaflex 61, vega vegaflex 61 guided wave radar level. To ensure reliable setup and operationof your vegaflex 61, we o. Vegaflex 81 is suitable for applications with liquids in small vessels under ordinary process conditions. If vegaflex 61 is equipped with an indicating and adjustment module, the most important data can be read out of the sensor into indicating and adjustment module. Operating instructions vegapuls 61 4 20 mahart fourwire. For safety and warranty reasons, any invasive work on the device beyond that described in the operating instructions manual. Make sure that theprobe does not touch the tube during operation.